pentaerythritol gear flow sensor

Date:2017-01-21 source:

  pentaerythritol gear flow sensor  

email: porter@microflowmeter.com  Shanghai JSN Micro Flow Meter CO.,LTD is located inShanghai Songjiang industry zone,with good location and convenienttransportation. We are the professional producer for micro flow meter,oval gearflow meter ,coriolis mass flow meter,electromagnetic flow meter,piston flowmete,gear flow meter,gear pump. We have rich experience incorporate management and production practice, especially in recent years,through the introduction of advanced domestic and foreign manufacturingtechnology, so that the factory"s management level and technical level hasleapt to a new level.We produce each series of flow meter and gear pump, complete specifications,advanced technology, excellent production equipment, strong technical force,complete inspection methods, quality in line with relevant standardspromulgated by the state and ministries, reliable performance. Annual outputand sales are far ahead of the industry. We are willing to join handswith all companies, Chinese and foreign investors, and Sihai people are lookingforward to making friends in the world, making them profitable to customers andbeing honest in the world.

 pentaerythritol gear flow sensor

pentaerythritol gear flow sensor

At presentdomestic Oval gear flow meter structure is complex, bulky, bulky, noisy, smallscale, not suitable for low viscosity liquid, the market is more common withDTO series and OGM series. For these problems the country has been unable toovercome, while the Shanghai JiShen instrument Instrument company oval gear Ovalgear flow meter does not have the above problems, such as the same DN25caliber, our model CX-M25-AL, flow range: 0.5 ~ 100L / M, range of 1: 200 orhigher, and weighs only 1.5KG , While the DTO-25, the flow of 600-6000L / H,range ratio of only 1:10, the weight of up to 23KG. All this due totechnological breakthroughs, our chief engineer Tu workers, he is a formerSiemens senior engineer, the use of equipment It is also Siemens CNC MachiningCenter with cutting accuracy up to 0.001mm, which ensures that we produce highquality flow meters.

Oval gear flow meter, belonging to a type of volumetric flowmeter,cylindrical shape, with import and export, according to the media with a customfilter. Small size, light weight, easy installation, compact structure, withouttoo much maintenance; other The range ratio is very wide, generally more than1: 100, the minimum flow rate can be measured to 0.3ml / min; and thelinearization accuracy can reach 0.5% FS of full scale, so the use is very wideand can be used for measuring, regulating, controlling and distributing Highand low viscosity, or corrosive liquids, and there are health-type,explosion-proof for a special environment.

gear flow sensor

pentaerythritol gear flow sensor

The CX-M and G series gearflow meters consist of a flow transmitter and a display. The oval gear flowmeter metering chamber of the flow transmitter has a pair of elliptical orcircular measuring gears. The gears and the measuring chamber form severalknown volumes. The cavity acts as a metering unit. Under the influence of thedifferential pressure between the inlet and outlet, the gear is driven torotate, and the imported liquid is continuously metered into the outlet aftermeasuring the metering chamber. At the same time, the sensor generates acorresponding electrical signal and sends it to the display section. Afterpartial treatment, the instantaneous flow and cumulative flow of the liquid canbe displayed.

 pentaerythritol gear flow sensor

pentaerythritol gear flow sensor


Item

model

K-factor

The minimum flow

Flow range

Connection size

Gear flow meter

CX-G0.025-P-AL

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.025-P-SS

0.025ml

0.001L/Min

0.004~1 L/min

G1/8

gear flow meter

CX-G0.04-P-AL

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.04-P-SS

0.04ml

0.004L/min

0.01~2L/min

G1/4

gear flow meter

CX-G0.1-P-AL

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.1-P-SS

0.1ml

0.008L/min

0.02~4L/min

G3/8

gear flow meter

CX-G0.2-P-AL

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.2-P-SS

0.245ml

0.01L/Min

0.08~8L/min

G3/8

gear flow meter

CX-G0.4-P-AL

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G0.4-P-SS

0.4ml

0.01L/Min

0.1~20L/min

G1/2

gear flow meter

CX-G1-P-AL

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G1-P-SS

1ml

0.02L/Min

0.2~40L/min

G1/2

gear flow meter

CX-G2-P-AL

2ml

0.04L/Min

0.5-60L/min

G3/4

gear flow meter

CX-G2-P-SS

2ml

0.04L/Min

0.5-60L/min

G3/4

Remark: Hightemperature, high pressure, high frequency, special connection, specialmaterials, two-way measurement, etc. can be customized


What are the precautions for the gear flow meter?

1) When the flow exceeds the specified maximum flow rate, the Oval gear flow meter wear increases with the increase of the rotation speed, and the pressure loss increases sharply, should be avoided. Less than the minimum flow, although still able to measure, but the error increases. Flow meter The starting flow is about 2% of the maximum flow, and the normal working flow is preferably 70%-80% of the maximum flow.

2) Deep-rooted flowmeter is used with various viscosity media from 0.3 ~ 100000cps, different viscosity media will affect the range, the following single must be noted

3) The measured liquid temperature should not exceed the specified value, otherwise, the instrument can not work properly, or even stuck, the counter part is easily damaged at high temperatures. Liquid temperature changes will also cause additional errors in viscosity.

Share to:


© 2016 Shanghai JSN Micro Flow Meter CO.,LTD  All rights reserved  Shanghai ICP preparation 07036704-1Map | Contact